Products

/Products/
  • adaptica - 2win
    The 2WIN is a mobile binocular video refractometer and vision analyzer that measures both eyes at the same time, in real life vision conditions. It embodies the best and the most complete technologies to fully detect refractive errors, eye abnormalities and vision problems. It measures in the range of -15D to +15D for automatic measurement of dynamic pupils response to programmable light stimulations, and accurately center spectacle lenses.
  • Random_Dot2_lg
    Designed to rapidly test for amblyopia and strabismus in early and non-readers and non-verbal children& adults. Expanded Random Dot Lea Symbols Test (500, 250, 125 seconds of arc). Graded circle test now down to 12.5 seconds with no monocular clues. New improved booklet has answer key on back cover and includes polarized viewers.
    • Expanded Random Dot Lea Symbols Test
    • Graded circle test now down to 12.5 seconds
    • No monocular clues with NEW technology
    • New improved booklet
    • Imprinted images inside booklet for matching
    • Answer Key on back cover
    • Includes both adult and pediatric polarized viewers
  • ellex ultra qellex ultra q
    ellec ultra qConsidered to be the industry’s leading microsurgical YAG laser, Ultra Q™ features a patented, proprietary cavity and a custom power supply, which allow you to perform capsulotomy and iridotomy procedures at lower, more efficient power levels and with greater shot-to-shot consistency. It is also the world’s fastest YAG laser, with a firing rate of 3 shots per second.

    IOL-Friendly Photodisruption

    Ultra Q™ achieves the industry’s lowest energy optical breakdown at 1.8mJ (in air) to cut tissue more efficiently with fewer shots and less cumulative energy. Featuring an Ultra Gaussian beam profile, Ultra Q™ focuses more energy into the center of the beam profile to deliver greater energy density. Not only does this reduce the amount of energy needed to effectively perform capsulotomy and iridotomy treatments, it also greatly reduces the risk of lens pitting.

    Capsulotomy for Presbyopic IOLs

    A precise capsulotomy is essential for IOLs that correct presbyopia through implantation in the posterior chamber’s capsular bag. Good IOL centration, in terms of the pupil, optimizes lens performance. In contrast, decentration can cause halos and poor vision. The goal is a perfectly centered, precise capsulotomy that will not affect the tension of the bag and the position of the IOL in the visual axis. The precision and ultra-low energy optical breakdown provided by Ultra Q™ creates a capsulotomy opening that is precisely controlled, without causing damage to the lens – even if the lack of a ridge makes the capsule adhere to the optic.

    Iridotomy for Phakic IOLs

    Refractive IOLs that are designed to correct myopia, or hyperopia (also known as Phakic IOLs) can be placed in front of the iris or between the iris and the natural lens. To prevent any possibility of IOL-induced pupillary block, these lenses require peripheral iridotomies prior to surgery. The iridotomy aperture must be large enough to ensure a balanced aqueous flow, yet small enough so that no light is transmitted back to the pupil, which can cause double vision. Ultra Q™ enables you to create a precise size of the iridotomy, often in a single shot that uses lower energy than other YAG lasers.

    Selective Capsulotomy

    Selective Capsulotomy performed with Ultra Q™ can effectively address ACCS and PCCS associated with the implantation of accommodative IOLs – allowing refinement of refractive outcomes following IOL surgery.
  • Gonio PrismGonio Prism
    Ideal for use with children or patients with a small palpebral fissure. The instrument consists of a highly polished truncated silver surfaced pyramid with a plane anteroir viewing surface over four mirrors. An aluminum handle set at 35 degrees is bonded to one corner of the lens. The lens is used in the diamond position (45 degrees) resulting in fewer adjustments of lowering and elevating the slit beam with either hand. Item #: OCIOPDSG
  • Multi Acuity Projector Slide
    Designed for use in manual Chart Projectors including products from: R.H. Burton, Marco, Reichart, Topcon, and Woodlyn. Includes test for: → Sloan Letters 20/400 – 20/15 (15 Lines) → Tumbling E 20/200 – 20/25 (9 Lines) → Allen Acuity 20/200 – 20/30 (6 Lines) Item #: VA1192
  • Red Green Tranaglyph
    Variable Tranaglyph™ Kit (600 Series) Appropriate for a wide range of problems including strabismic and non-strabismic orthoptics. Fusional convergence/divergence range is from ortho to 30PD, 10.5" x 5.5" red/green targets are on transparent vinyl. Use with Polachrome Trainer as a cost-effective alternative to Polaroid vectograms. Item #: BC600K+
  • Silver Pupilometer
    The Digital Pupilometer is a digital precision optical instrument designed for accuracy but with ease of use in mind as well. The device uses corneal reflection alignment system with high accuracy digital linear sensors. The large LCD screen provides easy reading for the technician. The measuring range is 46mm to 82mm binocular and 23mm to 41mm monocular. Includes automatic standby after 2 minutes of non-use to preserve battery life. This lightweight unit is powered by 4 AA batteries (not included).
  • Butterfly Acuity Test with Lea Symbols
    Butterfly Acuity Test with Lea SYMBOLS® Test designed to rapidly test for amblyopia & strabismus using gross thru fine stereopsis (4800 to 20 sec of arc) - Graded Circle Test from 800 sec now down to 20 sec - No monocular clues - New improved booklets - Answer Key on back cover - Includes polarized viewers
  • Bernell Deluxe VT Starter System
    Designed with a larger assortment of products. Utilizes the most advanced techniques in vision therapy in one complete system.
  • Vectogram Spirangle
    8-1/4" x 5-1/2" Polarized vectograms ensure testing and training at actual distances. Vectograms stabilize fusion and steropsis, eliminate supression and develop simultaneous vision. Used in monocular and binocular, pursuit and saccadic training, vectograms help correct and prevent anomalies involving projection and hand eye coordination. Ideal for use with Bernell's Dual Polachrome™ Trainer
  • Nidek Tabletop Refraction System TS-310
    • Simple and reliable refraction
    • Triple-performance combination
    • Flexible measurement style
    • Easy installation
    • Compact footprint
  • PART #VSFNC Often referred to as a ‘Super 90D’ this lens provides wide field imaging out to the mid periphery and dynamic viewing out to the periphery. This lens is a great choice for pan-retinal examination. This lens provides the magnification of a 90D, with an increased field of view enabling high resolution imaging of the posterior pole. This combination of magnification and wide field imaging allows quick and comprehensive examination of the retina, making it a go-to lens for general examination. A 30 mm lens ring provides a comfortable grip and manipulation of the lens within the orbit.