Bernell

//Bernell
  • Stereophotos
    These photographs come on heavy-duty 8-1/2" x 11" cardstock for durability. There are activity suggestions printed on the back of each card. Some photos are identical in everything except the type of vergence demand or the amount of vergence demand. These were designed for the offices who work with just noticeable differences (JND) with their patients. Item #: HDSPVP
  • Phoria CardPhoria Card 1
    Phoria Cards Test vertical and horizontal muscle balance at near and far. Used with Maddox Rod and Penlight. Referral considerations indicated on cards for imbalance beyond certain prism diopters or balance beyond specified esophoria and exophoria ranges. Shows phoria to parents!
    Item #: BC1209+
  • Variable Tranaglyph Slide - Bunny (600 Series)Fixed Demand Tranaglyph Kit
    Variable Tranaglyph™ Kit (600 Series) Appropriate for a wide range of problems including strabismic and non-strabismic orthoptics. Fusional convergence/divergence range is from ortho to 30PD, 10.5" x 5.5" red/green targets are on transparent vinyl. Use with Polachrome Trainer as a cost-effective alternative to Polaroid vectograms. Item #: BC600K+
  • TNO Test for Steroscopic Vision
    Suitable for testing very small children (2 1/2 to 5) as well as adults. Three plates for screening, 3 for diagnostic. Kit includes seven plates and red/green glasses.
  • LEA Numbers ETDRS Translucent Chart
    Adult LEA NUMBERS® chart for ETDRS Illuminated light boxes. Fits all existing ETDRS cabinets including both the ESV3000 and ESC2000. LEA NUMBERS® ETDRS chart contains optotypes in proportionally spaced (logMAR) lines; lines range from 20/200 to 20/8 (6/60 to 6/2.4) equivalent, 0.10 to 2.50. Fits in ESV3000 ETDRS illuminated cabinet.
  • Eccentric Circles - Transparent
    The new clear fixation paddle is 12" x 12" made of clear polycarbonate. Uses targets with cling material which adheres and removes easily from the front or back of the paddles by adhesion forces.
  • Yoked Rotating Prism - Child Size
    Set for Children Case with yoked rotating prisms for children. The set includes: 4 empty children's frame, 2 red and 2 blue. Plastic frame with nasal anatomical fit for children and adjustable elastic. Central screw for locking and unlocking the prisms. A pair of high quality plastic prisms for each power: 1, 2, 3, 5, 8, 10, 15, 20 PD. The power is cut on the prism's surface near the apex together with tactile notch. Item #: E/RYPSETC
  • Bernell Red/Green and Polarized Combo Flipper
    Flipper features two sets of lenses to alternate demand. Used with Vectograms or Tranaglyphs to reverse Base-In/Base-Out demands. Item #: BC1270RGP
  • Phoria Measure
    A Hand Held instrument to Measure a Maddox Phoria. This tests for anisophorias, vertical and horizontal, in all positions of gaze in real space instead of behind of phropter. Scale from 0 to 10 PD 25mm Item #: BC1211
  • Pediatric OKN Banner Adapter 1Pediatric OKN Banner Adapter
    Sized to fit over our Adult Optokinetic Drum (DAL300) this vinyl sheet is used to test for the optokinetic reflex. The banner has child interest targets similar to our DAL301. Can be rolled up for easy storage. Clear end pieces hold banner from curling. Washable plastic material similar to window shade. Velcro on backside of the banner allows for easy attachment around the Adult Optokinetic Drum (DAL300). Item #: OKNADP1
  • A.M.A. Near Point Test Card
    This much requested Near Acuity Card was originally developed by the American Optometric Association.
  • Pediatric Projector Slide
    Vectographic Projector Slide Pediatric Slide This pediatric projector slide test depth perception and binocularity under distance conditions. The top portion of each slide is a standard non-vectographic projector slide. The bottom portion is a vetographic slide that contains suppression control targets, a distance stereo acuity test, fixation disparity and binocular balance. Slide fits most AO and Marco projectors, and there are adaptable to a 10' or 20' lane. REQUIRES POLARIZING SCREEN.
  • Spatial Localization Board – VTE
    The Spatial Board was suggested by Dr. Streff as a way of quantifying and recording spatial localization shifts with patients. Dr. Kraskin utilized similar assessments of a patient's spatial localization in order to determine the amount and direction of yoked prisms to prescribe. The VTE Spatial Localization Board is designed for clinical efficiency to allow the behavioural optometrist to quickly assess a patient's spatial localization in real space and time; determine x, y and z axis spatial warps in 9 primary meridians; record patient responses for pre and post test data (especially good for documenting mid-line shifts in TBI and strabismic patients) and quantify immediate effects of lenses and prisms.
  • Basic Vertical Cards
    Basic Vertical Dr. Only Starter for any patient into fusion, anti-suppression and ranges of fusion. Set of 10 Cards For use with Bernell-O-Scope™ Item #: SMBV
  • Loose Risley Prism (Pair)
    Fits into the standard 38 mm eyewell of the Bernell-O-Scope or any standard trial lens frame. Each prism yields 20 PD for a total of 40PD. Now you can set any amount of BI, BO, or vertical prism into the stereoscope to do training procedures. May be used for distance training by removing the cardholder. Item #: ARPHH20
  • Bernell Red/Green Flipper
    Red/Green Flippers Quality, four-well flipper bar features two alternating sets of red and green lenses. Reverses Base-In/Base-Out demand with each flip. Item #: BC1270RG
  • ColorDx Pediatric 15
    Same great test, but in a new and improved package! The ColorDx Pediatric 15 is the newest version of Color Vision Testing Made Easy or CVTME. As the Gold Standard pediatric assessment of color deficiencies or color blindness See The Multi-Ethnic Pediatric Eye Disease Study published by the AAO, CVTME™ is used in over 40 countries and has been validated for illiterates at the US Special Olympics. Featuring the proven Waggoner six confusion-color strategy, the pediatric test is used in a broad range of settings: pediatrics, eye physicians, school nurses, and many other disciplines of health care, in any language, world-wide. This easy to administer test features both hidden and non-hidden shapes that allow for positive reinforcement even while testing color deficient children by allowing successful answers on most targets. This success-reinforced strategy is also useful for assessment of malingering. Designed by color vision expert Dr. Terrace Waggoner, this new edition features enhanced digital colorimetery production methods, durable page and binding materials, and magnetic light-protective storage case and enhanced digital colorimetery production method and durable page materials and binding. Brilliantly simple to take, easy to score and just plain fun for children.
  • Multiacuity Projector Slide
    Projector Slide Replacements MultiAcuity Projector Slide Letter Acuity, Tumbling "E", Allen Figure Test This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
  • Black Background TranaglyphBlack Background Tranaglyph
    These offer excellent cancellation with no ghost images. These fixed demand targets provide flat fusion from 1-3 prism diopters, 2nd & 3rd degree fusion from 4-28 PD. BI & BO therapy is possible using a R/G flipper or switching the lenses in the goggles. (Set of 5 cards and one R/G Flipper)
  • Vectogram Figure Eight
    7-1/2" x 5-1/2" Non-Variable Polarized vectograms ensure testing and training at actuall distances. vectograms stabalize fusion and steropsis, eliminates suppression and develop simulatneous vision. Used in monocular, binocular pursuit and saccadic training, vectograms help correct and prevent anomalies involving projection and hand eye coordination. Ideal for use with Bernell's Dual Polachrome™ Trainer
  • Vergence FacilityVergence Facility 12D BO and 3D BI
    A good binocular screening device. Performed at a distance of 40 cm with a target of 20/30. Most normal patients can cycle between these prims 15/minute. Those with difficulty should be more thoroughly tested. 12D Base-Out and 3D Base-In. Prism is 1.5 inches square. Item #: G1110+
  • Bernell Necklace 3D Variable Tranaglyph 1Bernell Necklace 3D Variable Tranaglyph
    New 3D Modeled Variable Tranaglyph. Comparable to the popular Quoit Vectogram.
  • Variable Tranaglyph AVariable Tranaglyph
    Variable Tranaglyph™ Kit (500 Series) Variable prismatic red/green slides help build initial fusional reserves through peripheral and central fusion as well as stereopsis. Effective home training slides feature 5.5" x 10.5" red/green targets on transparent vinyl. Item #: BC500+
  • Lea Symbols Pocket Near Card
    Pediatric near vision card featuring LEA Symbols pediatric symbols for testing children or illiterate adults at 16" (40 cm). It's small size makes it easy to carry or store. Front side contains proportionally-spaced lines in logarithmic progression with line sizes ranging from 20/400 to 20/10 (6/120 to 6/3) equivalent. The reverse side features pediatric symbols in 50% spaced rectangle (Massachusetts Visual Acuity Test format). Line sizes range from from 20/100 to 20/16 (6/30 to 6/4.8).
  • Lea Numbers Pocked Sized Near Card
    This test is designed for testing patients' visual acuity during rounds and in similar situations with a need for quick testing. The test has proportionally spaced (logMAR) lines on one side and tightly crowded lines (50% spacing) on the reverse side Line sizes from 20/400 to 20/10 (6/120 to 6/3) equivalent, 0.05 to 2.00. 3.75" x 6.25" (9.5 cm x 15.9 cm).
  • Full Color Aperture Rule Cards
    Aperture Rule™ Set (12 Stereoscope sized cards) These cares are more complex and require more detail demand. They build flexibility, resiliency, attention to detail and reduction of visual fatigue. These cards contain large quantities of details and build large ranges of fusion (leading to high amounts of prism diopters of 'Base Out' and 'Base In' fusion ranges) 12 Cards
  • Yoked Rotating Prism Set for Adults - VTE
    Case with yoked rotating prisms with clips of positive and negative lenses and red-green filters to add. The clips enhances the possible use of the glasses and make their use during VT more versatile. High quality plastic prisms. The prismatic power is cut on the surface near the prism's apex together a tactile notch. Each plastic clip has a sticker that is visible from both sides, with the power of the lens and has a shape designed to make the fitting on the frame easy. The set includes: 2 empty plastic frames with nasal anatomical fit and adjustable elastic, central screw for locking and unlocking the prisms, and a pair of prisms for each power: 1, 2, 3, 4, 5, 8, 10, 15, 20, 25 PD. Also included is: A pair of clips for each spherical power with binoncave and biconvex lenses: +.50, +1.00. +1.50, +2.00, +2.50, +3.00, -1.00, -2.00, -3.00, -4.00, -5.00, -6.00D; 1 green filter clip; and 1 red filter clip. Item #: E/RYPSETA1
  • Family Practice Projector Slide
    Designed for use in manual Chart Projectors including products from: R.H. Burton, Marco, Reichart, Topcon, and Woodlyn. Includes test for: → Tumbling E 20/400 – 20/200 (3 Lines) → Sloan Letters 20/100 – 20/10 (11 Lines) → Astigmatic Clock → Sloan Letters 20/50 – 20/10 (6 Lines) → Tumbling E 20/50 – 20/15 (5 Lines) → Allen Acuity 20/100 – 20/40 (4 Lines) Item #: VA1193
  • SMD card
    A durable home monitoring test card for those patients needing to detect metamorphopsia. Espically useful with ARMD and PMF. The back of the card contains near point reading material of various type sizes. This allows the patient to monitor possible changes in visual acutiy. The card is made of a washable plastic material. Size 5-1/2" by 8" Item #: BC11980
  • Worth 4-Dot Flashlight
    Worth 4-Dot Test Flashlight Used for testing and training of fusion, suppression, and/or diplopia. Red/Green goggle included. Requires 2 C batteries (not included).
  • Adult Acuity Slide
    Projector Slide Replacements Adult Acutiy Projector Slide Letter Acuity, Number Acuity, and Tumbling "E" Test This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
  • This screening battery is designed to detet vision problems in the pre-school population. It includes a test for visual acuity, eye alignment, binocular funtcion, farsightedness, lazy eye (amblyopia), and more. Utilizing new test such as the school bus test, this screening test for a great number of problems in a short period of time. This screening battery of test was designed for use by school personnel of members of service clubs such as Lions or Kiwanis with minimal training. Many test are pass/fail
  • Spatial Mapping - VTE
    Tumbling E Pad (Pad of 100) Printed with large 20/200 E on one side and a series of five 20/20 tumbling Es on the other- calibrated to a 20ft. distance. May be used to test and train peripheral awareness.
  • Convergence A Cards
    Morgenstern Color Fusion Cards - Convergence A Dr. Only Used with Bernell-O-Scope™ CONVERGENCE A. TRADITIONAL VT FOR FUSION RANGES & JUMP DUCTIONS WITH COLORFUL TARGETS. INCREASE IN DEMAND AND RANGE OF FLEXIBILITY. Item #: SMCA
  • Loose Risley Prism 20 (Single)
    Fits into the standard 38 mm eyewall of the Bernell-O-Scope™ or and standard trial lens frame. Each prism yields 20 PD for a total of 40PD. Now you can set any amount of BI, BO, or vertical prism into the stereoscope to do training procedures. May be used for distance training by removing the cardholder. It may also be used with the new Bernell 3-D videos. Item #: ARPHH20S
  • Mini Variable Vectogram
    Improve vertical or horiontal fusional reserves. Dispense to patients wearing vertical prism or with low fusional reserves. Does not fit in Slide Illuminators. Used with the vertical mini-vecto kit (BC275MVK) and with the horizontal Mini-Vecto Kit(BC216MVK) Item #: BC29