Products

/Products/
  • The A-Scan Plus Connect® is designed to meet the demands of today’s refractive cataract surgery.  It is the single most effective solution for measuring and calculating all of your patients and refining your surgical outcomes.  It has the ability to measure most patients and works great with dense cataracts or patients with fixation difficulties. The Connect links directly to a PC, laptop or tablet device making it the ultimate portable solution. Information can easily be uploaded to electronic medical record (EMR) systems. The improved user interface makes entering patient data, capturing the scan and calculating the measurement much faster.* Features:
    • Immersion and Contact Modes.
    • Industry Leading Resolution.
    • User-friendly interface.
    • Less Patient Chair Time – Faster measurement capture*.
    • Automatic Alignment Detection and Sclera Recognition eliminate marginally aligned scans.
    • Portable, Lightweight Design – Plug into any PC, laptop or tablet device.
    • Share information easily – adaptable document transfer via EMR, email or printer.
    • Modern Third and Fourth Generation Formulas including the Hoffer®Q, SRK/T, Holladay, Haigis as well as new post refractive formulas.
    • Optimized Lens Constants for superior surgical outcomes.
    • Unlimited Software Licenses.
    • Streamline your patient data - shares information with B-Scan Plus and UBM Plus.
    *When compared to original A-Scan Plus
  • oculus - corvisoculus_corvis_tonometer
    The revolutionary OCULUS Corvis® STL records the reaction of the cornea to a defined air pulse with a newly developed high-speed Scheimpflug-camera that takes over 4,300 images per second. IOP and corneal thickness can be measured with great precision on the basis of the Scheimpflug images.

    Corneal Visualization Scheimpflug Technology

    The revolutionary OCULUS Corvis® STL records the reaction of the cornea to a defined air pulse with a newly developed high-speed Scheimpflug-camera that takes over 4,300 images per second. IOP and corneal thickness can be measured with great precision on the basis of the Scheimpflug images.

    Measurement and Display Options

    • IOP measurement
    • Measurement of the corneal thickness
    • Scheimpflug images of the 1st and 2nd applanation of the cornea
    • Slow-motion video of the corneal deformation as a result of the air pulse
    • Non-contact tonometer in combination with an ultra-high-speed camera for visualization of the deformation of the cornea in reaction to an air pulse (4,330 frames / sec.)
  • Accommodative Flipper - No Imprint BC1270NI-W
    Our Accommodative Flipper without the Bernell Imprint Test and train for accommodative facility, accommodative rock, positive/negative relative accommodation and convergence and fusional convergence reserves. May delay bifocal use with some early presbyopes. Assists in hyperopia screening and lens demonstrations. Durable, white plastic holds shape under low heat for lens insertion. Powers listed on handle. One pair plus; one pair minus. Select from +/- 0.25 to 4.00 diopters in 0.25 increments. Item #: BC1270NI+
  • Vision Exercises Kit
    Home Vision Exercises This full-color, forty-minute videotape that was developed by Dr. Joel N. Zaba features an introduction on vision and learning. It contains fourteen vision skills exercises: vision tracking, pursuits, saccadics, eye-hand coordination in sports/play, copying/writing, directionality, visual discrimination, size/shape awareness, vision/body movements and visual memory. Item #: JZ+
  • Physiological-Diplopia Cord TrainerPhysiological-Diplopia Cord Trainer
    Physiological-Diplopia Cord™  (Similar to Brock String) Inexpensive home use instrument for near training as well as to extend phy-dip training from near into distance. Utilizes physical diplopia for training suppression, binocularity and spatial localization. Heavy cord with colored beads. Sold by the dozen in 10' or 20' lengths. Item #: BC109+
  • Far Fixation Disparity Target
    Gem Polarized Variable Vectographic with Fixation Disparity Target → Stereopsis depth of 700 seconds of arc → Includes Fixation Disparity target with central Fusion Lock → 16 diopter range for Base-In (Divergence) Training → 24 diopter range for Base-Out (Convergence) Training → Total accommodation range of 40 diopters → New improved Vecto Guides → Now includes Therapy Binder → Now includes doctor and patient instruction manuals → Now includes Patient Vision Therapy Record Form → Includes Standard Polarized Viewers Item #: VA1060PL
  • Lea Symbols Pocket Near Card
    Pediatric near vision card featuring LEA Symbols pediatric symbols for testing children or illiterate adults at 16" (40 cm). It's small size makes it easy to carry or store. Front side contains proportionally-spaced lines in logarithmic progression with line sizes ranging from 20/400 to 20/10 (6/120 to 6/3) equivalent. The reverse side features pediatric symbols in 50% spaced rectangle (Massachusetts Visual Acuity Test format). Line sizes range from from 20/100 to 20/16 (6/30 to 6/4.8).
  • Lea Numbers Pocked Sized Near Card
    This test is designed for testing patients' visual acuity during rounds and in similar situations with a need for quick testing. The test has proportionally spaced (logMAR) lines on one side and tightly crowded lines (50% spacing) on the reverse side Line sizes from 20/400 to 20/10 (6/120 to 6/3) equivalent, 0.05 to 2.00. 3.75" x 6.25" (9.5 cm x 15.9 cm).
  • Eccentric Circles - Transparent
    The new clear fixation paddle is 12" x 12" made of clear polycarbonate. Uses targets with cling material which adheres and removes easily from the front or back of the paddles by adhesion forces.
  • PocketScope™ Ophthalmoscope
    Patented Welch Allyn Coaxial Vision optics, combined with 68 lenses in single-diopter steps, for the precision you need to conduct a quality eye exam.
  • Auto Ref / Keratometer

    ARK-1s / 1a / 1

    • Accurate refraction measurement
    • VA measurement with glare test (available for the ARK-1s)
    • Simple opacity assessment with retroillumination image (available for the ARK-1s / 1a)
    • Patient-friendly accommodation measurement (available for the ARK-1s / 1a)
    • Keratometry measurement with mire ring
  • The Lang Fixation Cubes have been designed by J. Lang for the assessment of eye fixation, motility, accommodation, convergence, for cover test, and to prepare the child for testing with the Lang-Stereotest® or the Lang-Stereopad®.

    5 child-friendly objects are presented on the side and the top of the cube. Some of them are also included in the two versions of the Lang-Stereotest® and of the Lang-Stereopad®, and on the Lang Fixation stick.

    The Cube has a red handle.

    Each turn of the cube shows a new object. The star on the top side and the other objects can also be used for the test of convergence.

  • Fly_Stereopsis_Test_LEA_lg

    Designed to rapidly test for amblyopia and strabismus using gross thru fine stereopsis (4800 to 20 seconds of arc). Graded circle test from 400 seconds now down to 20 seconds with no monocular clues. New improved booklet has answer key on back cover and includes polarized viewers.

    • Graded circle test from 400 seconds now down to 20 seconds
    • No monocular clues with NEW technology
    • New improved booklet
    • Answer key on back cover
    • Includes both adult and pediatric polarized viewers
  • oculus - Universal Trial Frame UB 5oculus - Universal Trial Frame UB 5
    Everyone who has anything to do with the prescription of eyeglasses has heard of OCULUS Universal Trial Frames. Function
    • Space for a total of 10 trial lenses of 28 mm diameter
    • PD range from 46-72 mm
    • Adjustable temple tilt and length
    • Smooth axis adjustment
    • CVD scale
  • MDEP.pdf
    This handheld circular pupillometer device is used for measuring different size pupils. It was developed and researched by Dr. Jack Richman, O.D., as part of the Massachusetts Drug Evaluation and Classification Program (MDEP). This pupil measurement device is used by law enforcement officers across the country to assist in determining whether people are possibly impaired and/or under the influence of drugs. The reverse side has expected pupil size in different lighting conditions for non-impaired people. Item #: MDEP
  • Lea Numbers and Letters Projector Slide
    Designed for use in manual Chart Projectors including products from: R.H. Burton, Marco, Reichart, Topcon, and Woodlyn. Includes test for: → LEA Numbers® 20/125 – 20/10 (17 Lines) (Multiple Lines 20/50 – 20/10) → Sloan Letters 20/400 – 20/10 (20 Lines) (Multiple Lines 20/50 – 20/10) Item #: VA3201
  • Vocational Near Test Card
    English reading card. Point notation on front; meter notation on back. 4 to 18-point type. Item #: BC1196670
  • Worth Test with Letters with Red Green Glasses
    Three Figure Worth Type Test This test is used for determining diplopia, suppression or fusion in children. Sturdy flashlight comes with red/green glasses. Chrome 8" long flashight with 3" extension included. Requires 2 to 3 D batteries depending on the handle length. Not Included.
  • Adult Acuity Slide
    Projector Slide Replacements Adult Acutiy Projector Slide Letter Acuity, Number Acuity, and Tumbling "E" Test This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
  • This screening battery is designed to detet vision problems in the pre-school population. It includes a test for visual acuity, eye alignment, binocular funtcion, farsightedness, lazy eye (amblyopia), and more. Utilizing new test such as the school bus test, this screening test for a great number of problems in a short period of time. This screening battery of test was designed for use by school personnel of members of service clubs such as Lions or Kiwanis with minimal training. Many test are pass/fail
  • Spatial Localization Board – VTE
    The Spatial Board was suggested by Dr. Streff as a way of quantifying and recording spatial localization shifts with patients. Dr. Kraskin utilized similar assessments of a patient's spatial localization in order to determine the amount and direction of yoked prisms to prescribe. The VTE Spatial Localization Board is designed for clinical efficiency to allow the behavioural optometrist to quickly assess a patient's spatial localization in real space and time; determine x, y and z axis spatial warps in 9 primary meridians; record patient responses for pre and post test data (especially good for documenting mid-line shifts in TBI and strabismic patients) and quantify immediate effects of lenses and prisms.
  • eye one product

    The intuitive diagnostic ultrasound platform

    If you’re searching for an easily reconfigurable ultrasound platform that covers all examination and measurement scan modes in an easy-to-use, compact design, Eye One™ is the solution you're looking for. From diagnostic A-Scan to high-frequency B-Scan, Eye One™ delivers comprehensive capability to meet your ultrasound needs for both the posterior and anterior segments.

  • YC200YC200
    Features
    • Refined laser delivery with lower energy
    • SLT mode
    • Clear and sharp field of view
    • Precise aiming beam
    • Optimized operating distance
    • Unique joystick
  • SLM-4 ER Digital Slit Lamp
    Features Binocular linkage Galileo style Five Steps Rotation magnification Large depth of field and high definition optical system Digital camera: image captured by button on handle Image system software based on Windows 2000/XP (optional)